null

A PROUD CANADIAN BUSINESS FOR OVER 30+ YEARS!

TEXONIC RXD240 240W 100V Commercial Zone Amplifier

No reviews yet Write a Review
SKU:
RXD240
$399.99
Shipping:
Calculated at Checkout
$399.99
  • RXM1 Amplifier Bracket
  • RXD series amplifier bracker

Description

Add dependable power to a medium-sized commercial sound system with the TEXONIC RXD240 Class-D zone amplifier.

The RXD240 delivers 240W for a distributed 100V speaker system or 2 × 120W for compatible 8-ohm speakers. Its compact half-rack design, professional line-level connections and efficient Class-D operation make it suitable for restaurants, retail stores, offices, clinics, studios and other business audio installations.

A Balanced Choice for Medium Speaker Systems

The RXD240 fits between compact 120W amplifiers and larger 480W models. It provides useful power for projects that have outgrown a small amplifier but do not require a high-capacity commercial system.

It can power multiple compatible ceiling, wall-mount, pendant or surface speakers across one main business audio area when the total speaker load is calculated correctly.

Recommended Business Applications

  • Restaurants and cafés
  • Retail stores and showrooms
  • Offices and staff areas
  • Clinics and waiting rooms
  • Salons and wellness studios
  • Training and meeting rooms
  • Small gyms and recreation spaces
  • Dedicated commercial audio zones

Understanding the Zone Amplifier Design

100V operation: The amplifier powers one 240W commercial speaker zone. All connected speakers receive the same incoming audio program.

8-ohm operation: The amplifier provides two 120W low-impedance channels for a compatible stereo or two-channel speaker system.

The term “zone amplifier” refers to the area powered by the amplifier. The RXD240 does not include independent source selection or built-in multi-zone music control.

External Music Source Required

The RXD240 is a power amplifier. It does not include built-in Bluetooth, Wi-Fi streaming, USB playback, microphone mixing, FM radio or source selection.

Connect a compatible music streamer, mixer, preamplifier, television audio output or other line-level audio source.

240W 100V Commercial Speaker Output

The 100V mode is designed for commercial speaker systems using multiple transformer-equipped speakers and longer cable runs.

Compatible speakers are connected in parallel. Select the required 100V wattage tap on each speaker, then add all selected tap values together to calculate the total amplifier load.

Adjust Each Speaker for the Required Sound Level

Every speaker does not need to use the same transformer tap. The power setting can be selected according to the sound level required at each location.

  • Use lower taps in offices, hallways and quiet waiting areas.
  • Use medium taps for dining spaces, retail floors and reception areas.
  • Use higher taps in larger rooms or areas with more background noise.
  • Recalculate the total speaker load whenever a tap setting changes.

Speaker Load and 20% Amplifier Reserve

The total wattage of all selected speaker taps must remain below the RXD240 amplifier’s 240W rating. Maintaining approximately 20% unused capacity provides practical headroom for normal commercial operation.

Rated 100V output: 240W

Recommended 20% reserve: 48W

Recommended maximum speaker-tap load: Approximately 192W

Calculate the load using the selected transformer taps—not the maximum power rating printed on each speaker unless the maximum tap is actually being used.

Example 100V Speaker Loads

6 speakers at 15W: 90W total load

8 speakers at 15W: 120W total load

10 speakers at 15W: 150W total load

12 speakers at 15W: 180W total load

These examples remain below the recommended 192W load. Final speaker quantity and tap settings should be selected according to the speaker model, placement, room acoustics and required volume.

2 × 120W Output for 8-Ohm Speakers

In low-impedance mode, the RXD240 delivers up to 120W per channel into compatible 8-ohm speakers.

This option can be used for a stereo installation or two properly designed low-impedance speaker circuits. Confirm the impedance and power handling of the connected speakers before operation.

Important Output Selection

Select either the 100V output or the 8-ohm output before connecting the speaker system.

Do not use both output types at the same time. Confirm the output selector position, total speaker load and wiring before turning on the amplifier.

RCA and Balanced Audio Connections

Stereo RCA connectors provide a convenient unbalanced line-level input for compatible consumer and commercial audio sources.

A balanced Euroblock input is also provided for professional audio equipment and longer signal-cable runs where better resistance to electrical noise may be required.

Link Output for Additional Amplifiers

The balanced link output can pass the incoming audio signal to another compatible amplifier. This allows several amplifiers to share one music source while powering separate speaker zones or different sections of a larger facility.

Selectable 180Hz High-Pass Filter

The built-in high-pass filter reduces frequencies below approximately 180Hz before they reach the speakers.

This can improve clarity and reduce unnecessary low-frequency stress when the amplifier is used with compact ceiling speakers, wall speakers or paging speakers that are not designed for deep bass.

Front-Panel Level and Tone Controls

Frequently used adjustments are available from the front panel after the source equipment and speakers have been connected.

  • Main input-level control
  • Bass adjustment at 100Hz
  • Treble adjustment at 10kHz
  • Signal-presence indicator
  • Clip-status indicator
  • Protection-status indicator
  • Power indicator and switch

Compact Half-Rack Installation

The compact chassis can be installed on a shelf, inside an equipment cabinet or in a professional AV rack using a compatible RXD Series mounting kit.

Optional mounting kits are available for installing one RXD amplifier or two compatible RXD amplifiers side by side in a standard 19-inch rack.

Protection for Commercial Operation

  • Short-circuit protection
  • Output-overload protection
  • High-temperature protection
  • Signal monitoring
  • Clip and protection indicators

If the clip or protection indicator remains active, reduce the source level and check the speaker load, wiring and amplifier ventilation before continuing operation.

Technical Specifications

Brand TEXONIC
Model / SKU RXD240
Amplifier Type Class-D commercial power/zone amplifier
100V Output 240W
Low-Impedance Output 2 × 120W at 8Ω
Input Sensitivity / Impedance 0.775V, 0dBu / 10kΩ
Audio Inputs Stereo RCA and balanced Euroblock
Additional Output Balanced link output
Frequency Response 80Hz–17kHz, +1dB / −3dB
Signal-to-Noise Ratio Greater than 80dB, A-weighted
Total Harmonic Distortion Less than 1% at rated power, 1kHz
Tone Controls Bass 100Hz ±10dB; treble 10kHz ±10dB
High-Pass Filter Selectable 180Hz, −3dB
Operating Temperature 0°C to 40°C
Power Requirement 110/230V AC, 50–60Hz
Power Consumption 325W
Mounting Shelf, cabinet or optional RXD rack-mount kit
Protection Short circuit, overload and high temperature

What’s Included

  • 1 × TEXONIC RXD240 amplifier
  • 1 × AC power cable
  • 1 × Speaker connection terminal
  • RXD240 user manual access

Warranty

TEXONIC RXD240 Amplifier: 2-Year Manufacturer’s Warranty

Need Help Planning the Speaker Load?

Send us the speaker models, quantities, selected 100V tap settings, audio-source equipment, room dimensions and installation requirements. We can help calculate the total speaker load and confirm whether the RXD240 is suitable for the project.